FERFA TYPE 4 · 1 TO 3MM · AGGREGATE DRESSED

Multi-Layer Resin Flooring for Grip and Wear

The system to specify when the floor has to grip and take punishment at the same time. Aggregate is broadcast into each coat and locked in by the next, so the texture runs through the build rather than sitting on the surface waiting to wear off. School corridors, vehicle workshops, ramps and wet production floors are its natural ground.

THE SPECIFICATION AT A GLANCE

Multi-Layer Resin Flooring, FeRFA Type 4

Multi-Layer Flooring

Multi-layer epoxy resin floor with broadcast aggregate
SystemMulti-Layer Resin Flooring
ClassificationFeRFA Type 4, aligned to BS 8204-6
DutyMedium to heavy duty
Typical thickness1 to 3 mm
Cost indicator£12 to £16 per square metre
Return to service24 to 48 hours
Application temperature15°C and above
THE SYSTEM, DEFINED

What Multi-Layer Resin Flooring Actually Is

Multi-layer is a sandwich rather than a film. Coats and aggregate alternate to build thickness and texture together, which is what separates it from a coating with grit added at the end.

Aggregate Between the Coats

Aggregate is broadcast into each coat and locked in by the next, building a sandwich rather than a film. The grip and the wear resistance are structural.

FeRFA Type 4, 1 to 3mm

Type 4 in the FeRFA classification aligned to BS 8204-6, sitting between a high build coating and a flow-applied floor in both thickness and duty.

Grip Built Into the Floor

Because the aggregate runs through the build rather than sitting on top, the texture does not wear off the traffic lines the way a surface treatment does.

SPECIFIED RIGHT, AND SPECIFIED WRONG

Where Multi-Layer Is the Right System

Where It Is the Right Call

Heavy foot traffic and light vehicle routes where grip matters: school corridors and halls, vehicle workshops and MOT bays, ramps, loading areas and wet production floors that do not face thermal shock.

Where It Is the Wrong Call

The texture that makes it work also makes it harder to clean, so it is the wrong instinct for a clean room or a hygiene-led area where a seamless smooth finish is the requirement.

WHAT WE MEASURE BEFORE WE QUOTE

Three Things That Decide the Build

Multi-layer is specified where grip and durability are both requirements. Getting the balance right means measuring both rather than defaulting to the roughest finish available.

Traffic and Grip Together

Multi-layer is specified where both matter at once. The aggregate grade is set against the traffic as well as against what gets spilled on the floor.

The Cleaning Method

Texture and cleanability pull against each other. We set the build at the point the floor stays safe underfoot and can still be cleaned by your method.

Build and Thickness

One to three millimetres covers a wide range of duty. Where the floor sits in that range is set by the loading, not by the area being covered.

THE TRADE-OFF, STATED

Grip and Cleanability Pull Against Each Other

Every aggregate specification is a compromise between two things a facility wants at the same time. More texture means better grip underfoot when the floor is wet or oily, and it also means more surface for soil to sit in and more effort to clean. Specifying the roughest finish available is not the safe option; it is a decision to make the floor harder to maintain.

So the grade is set against measured need rather than instinct. Slip resistance is specified to BS 7976 pendulum values, tested with the contamination actually present on your floor, and the cleaning method you already use is part of that conversation. A floor that is safe but never properly cleaned has solved one problem by creating another.

IF THIS IS NOT YOUR SYSTEM

The Other Resin Flooring Systems We Install

SPECIFY IT FROM THE SUBSTRATE UP

Find Out What Your Floor Actually Needs

We attend site, test the substrate and record the traffic, the contamination and how the floor is cleaned. The aggregate grade and the build come out of those findings rather than out of a product range.